Trustworthy Medical Segmentation: Uncertainty-Aware U-Net Evaluation Under Clinical Image Degradation
英文标题:Trustworthy Medical Segmentation: Uncertainty-Aware U-Net Evaluation Under Clinical Image Degradation
arXiv:2607.22727v1 Announce Type: new Abstract: Medical image segmentation models often report high benchmark accuracy under ideal imaging conditions, yet their failures under clinical degradation can be quiet: sensor noise, patient motion, low- resolution acquisition, and contrast variability may
640 B
612 B
380 B
9.1 KB
32.7 KB
22.8 KB
24.2 KB
34.7 KB
中文
arXiv:2607.22727v1 Announce Type: new Abstract: Medical image segmentation models often report high benchmark accuracy under ideal imaging conditions, yet their failures under clinical degradation can be quiet: sensor noise, patient motion, low- resolution acquisition, and contrast variability may
中文全文翻译正在补齐,可先查看下方英文原文。
English / 原文
[Submitted on 22 Jul 2026]
Title:Trustworthy Medical Segmentation: Uncertainty-Aware U-Net Evaluation Under Clinical Image Degradation
View a PDF of the paper titled Trustworthy Medical Segmentation: Uncertainty-Aware U-Net Evaluation Under Clinical Image Degradation, by Pranav Kaliaperumal and 1 other authors
Abstract:Medical image segmentation models often report high benchmark accuracy under ideal imaging conditions, yet their failures under clinical degradation can be quiet: sensor noise, patient motion, low- resolution acquisition, and contrast variability may all alter model behavior without producing an obvious warning. We present a reproducible framework for evaluating uncertainty-aware segmentation under con- trolled clinical degradation. Our experiments use a synthetic multimodal brain tumor MRI cohort generated with a biophysical phantom simulator that follows the BraTS protocol. We train U-Net and Attention U-Net baselines for multi-class tumor sub-region segmentation and augment both models with Monte Carlo dropout to estimate per-voxel uncertainty. Across eight clinically motivated corruption types at five severity levels, we measure segmentation accuracy, calibration, failure detection, and selective prediction coverage. On clean data, Attention U-Net achieves a whole-tumor Dice of 0.990; under severe Gaussian noise, its performance falls to 0.089. Predictive uncertainty rises with degradation and tracks segmentation error (Pearson r = 0.53 under severity-3 Gaussian noise), allowing us to flag failures with an AUROC of 0.843. These results argue for uncertainty-aware inference as a practical safety layer in physician-in-the-loop radiology workflows. We release the code, trained models, and evaluation protocol to support direct reproduction.
Submission history
From: Pranav Kumar Kaliaperumal [
]
[v1]
Wed, 22 Jul 2026 06:35:33 UTC (216 KB)